24kV Indoor Vacuum Circuit Breaker

Model: VN2-24E
Place of Origin: Zhejiang,China (Mainland)
Type: Vacuum
Poles Number: 3
Brand Name: PURANA
Rated Voltage: 24kV
Rated Current: 630-2500A
Rated Short Circuit Breaking Current: 20/25/31.5kA
Rated Peak Withstand Current: 50/63/80kA

inquiry

skype basketAdd to Basket  Edit

Share |

Product Description

Payment & Shipping Terms Supply Capacity
Payment Terms:L/C, T/T, WUProduction Capacity:1000 per month
Min. Order:1 Set/SetsPacking:In wooden cases
Means of Transport:Ocean, Air, LandDelivery Date:25 working days

VN2-24E indoor medium-voltage AC vacuum circuit breaker is a newest product designed by our company which is applicable to 3-phases AC50Hz, 24kV indoor switch systems. The product is with characteristics of smaller volume, reliable insulation, no pollution, long time free maintenance and so on. It is produced with standardized circuit breaker assembly line and has good performance and perfect quality.

Characteristics:

1. Equipped with modularized operating mechanism which make the maintenance and the replacing are more convenient. The replace of module do not affect the dynamic capability and also shorten the power-off duration.

2. The interrupter and primary circuit are sealed in the epoxy resin, which make the circuit breaker is more reliable.

3. The pole using converted and ventilated technique and lower resistance vacuum circuit breaker limit the temperature rising because of circuit breaker working for a long time and also reduce the power loss.

4. The operating mechanism is designed uniquely and avoid the moving contact over-rebounding when the circuit breaker is opened and prolong the vacuum interrupter mechanical life.

5. Past the type test according to the national standards, such as GB, DL, international standards of IEC, CEI, DIN, VDE and other major industrialized countries.

Main Technical Parameters of 24kV Vacuum Circuit Breaker
Rated Voltage
Rated VoltageUr[kV]24
1min power frequency withstand voltage(effective value)Ud(1min)[kV]Between phase
or phase to the earth
65Isolated
joints
79
Lightning impulse withstand voltage(peak value)Up[kV]125145
1min power frequency voltage of the secondary controlling circuit[V]2000
Power supply of controlling circuit[V]AC220, DC220/110
Rated frequencyFr[Hz]50/60
Rated operating sequence
O-0.3s-CO-180s-CO
Rated Current
Rated currentIr[A]630, 1250, 1600, 2000, 2500, 3150
Rated short-circuit breaking currentIcs[kA]20, 25, 31.5
Rated short-circuit making currentIu[kA]50, 63, 80
Rated short-time withstand currentIk[kA]20, 25, 31.5
Rated peaking withstand currentIp[kA]50, 63, 80
Rated capacitor bank breaking current[A]400
Rated capacitor bank making current[kA](4250Hz)20
Mechanical character
Mechanical lifetimeCycle20000
Electrical lifetime
E2
Opening time[ms]20~50
Arcing time[ms]≤15
Full breaking time[ms]30~65
Closing time[ms]35~70